Kaiyi BR380JG-1E0 — CONTENTS OF TROUBLESHOOTING TABLE

SEN02089-01 40 Troubleshooting Contents of troubleshooting table 1 a The following information is summarized in the troubleshooting table and the related electrical circuit diagram. Before carrying out troubleshooting, understand that information fully.

10 BR380JG-1E0 User code Failure code Trouble Names of the failure symptoms displayed in the failure history on the machine monitor Machine monitor display Machine monitor display Contents of trouble State where the machine monitor or controller detects the trouble Action of controller Action to be taken to protect the system and equipment when the machine monitor or control- ler detects a trouble Problem that appears on machine Problem that appears as an abnormality in the machine by the action (above) taken by monitor or controller Related information Information related to troubles occurred or troubleshooting Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Cause by which a trou- ble is assumed to be detected (The order number indicates a serial num- ber, not a priority sequence.) • Standard value when normal required to judge the possible cause • Remarks required to judge whether any cause is right or not • Disconnection in wiring The connector connection is defective or the wiring harness is disconnected.

• Defective grounding A harness not connected to GND (ground) circuit comes into contact with the GND (ground) circuit. • Hot short defect A harness not connected to the electric power supply (24V) cir- cuit comes into contact with the electric power supply (24V) cir- cuit. • Short circuit A harness abnormally comes into contact with a harness of sepa- rate circuit. (1) Method of indicating connector numbers and handling T-adapter For troubleshooting, insert or connect the T-adapter as described below unless especially specified. • When “male” or “female” is not indicated for a connector number, disconnect the connector, and insert the T- adapter in both the male and female.

• When “male” or “female” is indicated for a connector num- ber, disconnect the connector, and insert the T-adapter in only either the male or female. (2) Pin number description sequence and tester lead handling For troubleshooting, connect the plus (+) and minus (–) leads of the tester as described below unless especially specified. • Connect the plus (+) lead to a pin number or harness indi- cated in the front. • Connect the minus (–) lead to a pin number or harness indi- cated in the rear. 2 3 4