Kaiyi BR380JG-1E0 — TROUBLESHOOTING BY FAILURE CODE, PART 1

SEN02090-00 MOBILE CRUSHER 1SHOP MANUAL BR380JG-1E0 Machine model Serial number BR380JG-1E0 2001 and up 40 Troubleshooting 1 Troubleshooting by failure code, Part 1 Failure code [7RC1KB] Short circuit conveyor ON switch .............................................................................. 4 Failure code [7RC2KA] Disconnection in conveyor OFF switch ..................................................................... 6 Failure code [7RC5KB] Short circuit in feeder ON switch............................................................................... 8 Failure code [7RD2KB] Short circuit in conveyor reverse relay ....................................................................

10 Failure code [7RD2KZ] Disconnection or short circuit in conveyor reverse relay ......................................... 12 Failure code [7RE1KB] Short circuit in crusher ON switch ........................................................................... 14 Failure code [7RE2KA] Disconnection in crusher OFF switch...................................................................... 16 Failure code [7RE6KB] Short circuit in muck discharge conveyor ON switch .............................................. 18 Failure code [7RE7KA] Disconnection in muck discharge conveyor OFF switch .........................................

20 Failure code [7RE8KB] Short circuit in magnetic separator ON switch ........................................................ 22 Failure code [7RE9KA] Disconnection in magnetic separator OFF switch ................................................... 24 Failure code [7REAKB] Short circuit in accessory input circuit..................................................................... 26 Failure code [7REDMA] Abnormality in primary conveyor pressure sensor ................................................. 28 Failure code [7REEMA] Abnormality in muck conveyor pressure sensor.....................................................

30 Failure code [7RENKZ] Abnormality in clearance potentiometer.................................................................. 32 Failure code [7REPKA] Disconnection in feeder OFF switch ....................................................................... 34 BR380JG-1E0 1