SEN02090-00 40 Troubleshooting Failure code [7RC2KA] Disconnection in conveyor OFF switch 1 6 BR380JG-1E0 User code Failure code Trouble Disconnection in conveyor OFF switch (Work equipment and pump controller (work equipment control) system) — 7RC2KA Contents of trouble • Input signal circuit for the conveyor OFF switch is opened (disconnected from ground circuit) within 1 second after the engine starting switch ON. Action of controller • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF. • Turns all the output OFF for 1 second after turning the engine starting switch ON. • Turn OFF the output to conveyor normal rotation solenoid.
Problem that appears on machine • Conveyor does not work even if the conveyor ON switch is pressed. • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • Input state (ON/OFF) from the conveyor stop switch can be checked with the monitoring function (Code: 25000, Switch Input 0). • The failure history is recorded. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective conveyor OFF switch aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. B72A (male) Conveyor OFF switch Resistance Between (1) and (2) ON Min. 1 Mz OFF Max.
1 z 2 Disconnection in wiring harness (Disconnec- tion in wiring or defec- tive contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C02 (female) (5) – B72A (female) (2) Resistance Max. 1 z Wiring harness between B72A (female) (1) and chassis ground Resistance Max. 1 z 3 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C02 (female) Resistance Between (5) and chassis ground Max. 1 z