Kaiyi BR380JG-1E0 — FAILURE CODE [7RC5KB] SHORT CIRCUIT IN FEEDER ON SWITCH

SEN02090-00 40 Troubleshooting Failure code [7RC5KB] Short circuit in feeder ON switch 1 ( 8 BR380JG-1E0 User code Failure code Trouble Short circuit in feeder ON switch (Work equipment and pump controller (work equipment control) system) — 7RC5KB Contents of trouble • Input signal circuit for the feeder ON switch is closed (connected to ground circuit) within 1 second after the engine starting switch ON. Action of controller • Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF. • Turns all the output OFF for 1 second after turning the engine starting switch ON.

• Output to the feeder normal rotation EPC does not turn ON even if the feeder ON switch is pressed. Problem that appears on machine • Feeder does not work even if feeder ON switch is pressed. • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • Input state (ON/OFF) from the conveyor feeder ON switch can be checked with the monitoring fusion (Code: 25000, Switch Input 0). • The failure history is recorded.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective feeder ON switch aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. B71C (male) Feeder ON switch Resistance Between (1) and (2) ON Max. 1 z OFF Min. 1 Mz 2 Grounding fault in wir- ing harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (10) – A20 – A44 – A33 (female) (10) and chassis ground Resistance Min.

1 Mz Wiring harness between C03 (female) (10) – B71C (female) (2) and chassis ground Resistance Min. 1 Mz 3 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C03 (female) Feeder ON switch Resistance Between (10) and chassis ground ON Max. 1 z OFF Min. 1 Mz