Kaiyi BR380JG-1E0 — FAILURE CODE [7RD2KB] SHORT CIRCUIT IN CONVEYOR REVERSE RELAY

SEN02090-00 40 Troubleshooting Failure code [7RD2KB] Short circuit in conveyor reverse relay 1 10 BR380JG-1E0 User code Failure code Trouble Short circuit in conveyor reverse relay (Work equipment and pump controller (work equipment control) system) — 7RD2KB Contents of trouble • Abnormal voltage is detected when output to the discharge conveyor reverse relay is ON. Action of controller • Turn OFF the output to discharge conveyor reverse rotation relay. • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF. Problem that appears on machine • Discharge conveyor reverse rotation does not work.

• Horn sounds (three intermittent sounding) upon detecting a failure. Related information • The failure history is recorded. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective discharge conveyor reverse rota- tion relay (Internal short circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. R17 (male) Resistance Between (1) and (2) 100 – 500 z Between (3) and (5) Min. 1 Mz 2 Grounding fault in wir- ing harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting.

Wiring harness between C03 (female) (8) – R17 (female) (1) and chassis ground Resistance Min. 1 Mz 3 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. C03 (female) Conveyor manual reverse rotation switch Voltage Between (8) and chassis ground ON 20 – 30 V OFF Max. 1 V