SEN02090-00 40 Troubleshooting Failure code [7RD2KZ] Disconnection or short circuit in conveyor reverse relay 1 12 BR380JG-1E0 User code Failure code Trouble Disconnection or short circuit in conveyor reverse relay (Work equipment and pump controller (work equipment control) system) — 7RD2KZ Contents of trouble • Abnormal voltage is detected when output to the discharge conveyor reverse rotation relay is OFF. Action of controller • Turn OFF the output to discharge conveyor reverse rotation relay. • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF. Problem that appears on machine • Discharge conveyor reverse rotation does not work.
• Horn sounds (three intermittent sounding) upon detecting a failure. Related information • The failure history is recorded. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse No. 6 If the fuse No. 6 is burn, the circuit probably has a grounding fault, etc. (See cause 4.) 2 Defective discharge conveyor reverse rota- tion relay aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. R17 (male) Resistance Between (1) and (2) 100 – 500 z Between (3) and (6) Max.
1 z 3 Disconnection in wiring harness (Disconnec- tion or defective con- tact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (8) – R17 (female) (1) Resistance Max. 1 z Wiring harness between R17 (female) (3) and B28No.6 Resistance Max. 1 z 4 Hot short in wiring har- ness (Contact with 24V circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (8) – R17 (female) (1) and chassis ground Voltage Max.
1 V 5 Defective work equip- ment an pump control- ler aPrepare with engine starting switch OFF and with mode selector switch at inspection mode, then turn engine starting switch ON and carry out troubleshooting. C03 (female) Conveyor manual reverse rotation switch Voltage Between (8) and chassis ground ON 20 – 30 V OFF Max. 1 V