SEN02090-00 40 Troubleshooting Failure code [7RE6KB] Short circuit in muck discharge conveyor ON switch 1 18 BR380JG-1E0 User code Failure code Trouble Short circuit in muck discharge conveyor ON switch (Work equipment and pump controller (work equipment control) system) — 7RE6KB Contents of trouble • Input signal circuit for the muck discharge conveyor ON switch is closed (connected to ground cir- cuit) within 1 second after the engine starting switch ON. Action of controller • Turn OFF the output to muck discharge conveyor solenoid. • Turns all the output OFF for 1 second after turning the engine starting switch ON.
• Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF. Problem that appears on machine • Muck discharge conveyor does not work even if the muck discharge conveyor ON switch is pressed. • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • Input state (ON/OFF) from the muck discharge conveyor starting switch can be checked with the monitoring function (Code: 25006, Switch Input 6). • The failure history is recorded.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective muck dis- charge conveyor ON switch aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. B71D (male) Muck discharge conveyor ON switch Resistance Between (1) and (2) ON Max. 1 z OFF Min. 1 Mz 2 Grounding fault in wir- ing harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C02 (female) (36) – B71D (female) (2) and chassis ground Resistance Min.
1 Mz 3 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C02 (female) Much discharge con- veyor ON switch Resistance Between (36) and chassis ground ON Max. 1 z OFF Min. 1 Mz