SEN02090-00 40 Troubleshooting Failure code [7RE8KB] Short circuit in magnetic separator ON switch 1 22 BR380JG-1E0 User code Failure code Trouble Short circuit in magnetic separator ON switch (Work equipment and pump controller (work equipment control) system) — 7RE8KB Contents of trouble • The magnetic separator ON switch input signal circuit is closed (connected to the chassis ground) in 1 second after the engine starting switch is turned ON. Action of controller • Turns OFF the output to the magnetic separator solenoid. • Turns all the output OFF for 1 second after turning the engine starting switch ON.
• Even if the cause of the failure disappears, the system does not reset itself until the engine starting switch is turned OFF. Problem that appears on machine • When the magnetic separator ON switch is depressed, the magnetic separator does not operate. • When this trouble is detected, the horn sounds (3 times intermittently). Related information • Input state (ON/OFF) from the magnetic separator ON switch can be checked with the monitoring function (Code: 25006, Switch Input 6). • The failure history is recorded.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective magnetic separator ON switch aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. B71E (male) Magnetic separator ON switch Resistance Between (1) and (2) ON Max. 1 z OFF Min. 1 Mz 2 Short circuit with chas- sis ground in wiring harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Between wiring harness between C02 (female) (3) and B71E (female) (2) and chassis ground Resistance Min.
1 Mz 3 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C02 (female) Magnetic separator ON switch Resistance Between (3) and chassis ground ON Max. 1 z OFF Min. 1 Mz