Kaiyi BR380JG-1E0 — FAILURE CODE [7RE9KA] DISCONNECTION IN MAGNETIC SEPARATOR OFF SWITCH

SEN02090-00 40 Troubleshooting Failure code [7RE9KA] Disconnection in magnetic separator OFF switch 1 24 BR380JG-1E0 User code Failure code Trouble Disconnection in magnetic separator OFF switch (Work equipment and pump controller (work equipment control) system) — 7RE9KA Contents of trouble • The magnetic separator OFF switch input signal circuit is opened (disconnected from the chassis ground) in 1 second after the engine starting switch is turned ON. Action of controller • Turns the magnetic separator OFF switch input OFF. • Turns all the output OFF for 1 second after turning the engine starting switch ON.

• Even if the cause of the failure disappears, the system does not reset itself until the engine starting switch is turned OFF. Problem that appears on machine • When the magnetic separator ON switch is depressed, the magnetic separator does not operate. • When this trouble is detected, the horn sounds (3 times intermittently). Related information • Input state (ON/OFF) from the magnetic separator OFF switch can be checked with the monitoring function (Code: 25006, Switch Input 6). • The failure history is recorded.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective magnetic separator OFF switch aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. B72E (male) Magnetic separator OFF switch Resistance Between (1) and (2) ON Min. 1 Mz OFF Max. 1 z 2 Disconnection in wiring harness (Disconnection in wir- ing harness or defec- tive contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C02 (female) (28) and B72E (female) (2) Resistance Max.

1 z Wiring harness between B72E (female) (1) and chassis ground Resistance Max. 1 z 3 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C02 (female) Resistance Between (28) and chassis ground Max. 1 z