SEN02090-00 40 Troubleshooting Failure code [7REAKB] Short circuit in accessory input circuit 1 26 BR380JG-1E0 User code Failure code Trouble Short circuit in accessory input circuit (Work equipment and pump controller (work equipment control) system) — 7REAKB Contents of trouble • Input signal circuit 1 for the accessory is closed (connected to power supply circuit) within 1 second after the engine starting switch ON. Action of controller • Turn OFF the output of the accessory drive EPC solenoid. • Turns all the output OFF for 1 second after turning the engine starting switch ON. • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF.
Problem that appears on machine • The machine does not work even if any of the conveyor up/down switch (2 switches) or side con- veyor up/down switch (2 switches) is pressed. • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • The input state (ON/OFF) from the accessory input circuit can be checked with the monitoring func- tion (Code: 25006, Switch Input 6). • The failure history is recorded. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective conveyor up switch aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON.
Between T82B (male) (1) and (2) Resistance Min. 1 Mz 2 Defective conveyor down switch aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Between T83B (male) (1) and (2) Resistance Min. 1 Mz 3 Hot short in wiring har- ness (Contact with 24 V circuit) aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. Wiring harness between C01 (female) (12) – T82B (male) (2) or T83B (male) (2) and chassis ground Voltage Max.
1 V 4 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Between C01 (female) (12) and chassis ground Resistance Min. 1 Mz