SEN02090-00 40 Troubleshooting Failure code [7REEMA] Abnormality in muck conveyor pressure sensor 1 30 BR380JG-1E0 User code Failure code Trouble Abnormality in muck conveyor pressure sensor (Work equipment and pump controller (work equipment control) system) — 7REEMA Contents of trouble • Signal voltage from the muck discharge conveyor pressure sensor is below 0.3 V or above 4.42 V. Action of controller • Mistakes muck discharge conveyor pressure for 0 MPa. • If cause of failure disappears, the system resets itself. Problem that appears on machine • Whole work equipment does not stop completely even if abnormal load is applied to the muck dis- charge conveyor.
(Primary conveyor, crusher, muck discharge conveyor, magnetic separator, vibra- tory screen, secondary conveyor and feeder) • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • If 5V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor will be broken. Accordingly, take extreme care when checking. • Input from the muck discharge conveyor pressure sensor can be checked with the monitoring func- tion (Code: 24400, Muck Conv. Pressure). • The failure history is recorded.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 5V sensor power source system If the Failure code [DA25KP] is displayed simultaneously, perform the troubleshooting for it first. 2 Defective muck dis- charge conveyor pres- sure sensor (Internal defect) aPrepare with engine starting switch OFF, then turn engine starting switch ON or start engine and carry out troubleshooting in each case.
aIf Items 3 – 5 are normal S02 Voltage Between (1) and (3) 4.5 – 5.5 V Between (1) and (2) 0.3 – 4.5 V If the voltage is normal, replace with another pressure sensor (pressure sensor of primary conveyor etc.) and check if failure codes are displayed. (If the E mark of the failure code disappears, the muck discharge conveyor pressure sensor is defective.) 3 Disconnection in wiring harness (Disconnection or defective contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C01 (female) (13) – A03 – S02 (female) (2) Resistance Max.
1 z Wiring harness between C01 (female) (4) or (10) A03 – S02 (female) (1) Resistance Max. 1 z Wiring harness between C01 (female) (22) – A02 – S02 (female) (3) Resistance Max. 1 z 4 Grounding fault in wiring harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. aDisconnect C01 and S02. Wiring harness between C01 (female) (13) – A03 – S02 (female) (2) and chassis ground Resistance Min. 1 Mz 5 Hot short in wiring har- ness (Contact with 24V circuit) aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. aDisconnect C01 and S02.
Wiring harness between C01 (female) (13) – A03 – S02 (female) (2) and chassis ground Voltage Max. 5 V 6 Defective work equip- ment and pump con- troller If causes 1 – 5 are not detected, work equipment and pump controller may be defective. (Since trouble is in system, troubleshooting cannot be car- ried out.)