Kaiyi BR380JG-1E0 — FAILURE CODE [7RENKZ] ABNORMALITY IN CLEARANCE POTENTIOMETER

SEN02090-00 40 Troubleshooting Failure code [7RENKZ] Abnormality in clearance potentiometer 1 32 BR380JG-1E0 User code Failure code Trouble Abnormality in clearance potentiometer (Work equipment and pump controller (work equipment control) system) — 7RENKZ Contents of trouble • Signal voltage from the clearance detection potentiometer is below 0.23 V or above 4.77 V. Action of controller • Stops full-auto or auto clearance adjustment. • Detects wrong clearance detection potentiometer value. • If cause of failure disappears, the system resets itself. Problem that appears on machine • Multi-monitor displays incorrect clearance value. • Wear limit warning is not issued.

• Clearance adjustment is disabled. • Crusher and feeder do not stop even if foreign matter is pinched in the auto/full-auto crusher and the movable jaw moves toward open position. Related information • The failure history is recorded. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 5V sensor power source system If the Failure code [DA25KP] is displayed simultaneously, perform the troubleshooting for it first. 2 Defective clearance detection potentiome- ter (Internal defect) Prepare with engine starting switch OFF, then turn engine starting switch ON or start engine and carry out troubleshooting in each case.

S12 (male) Resistance Between (A) – (C) 4.0 – 6.0 kz Between (B) – (A) 0.25 – 5.0 kz Between (B) – (C) 0.25 – 5.0 kz 3 Disconnection in wiring harness (Disconnection in wiring or defective contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C01 (female) (22) – S12 (female) (C) Resistance Max. 1 z Wiring harness between C01 (female) (21) – S12 (female) (A) Resistance Max. 1 z Wiring harness between C01 (female) (14) – S12 (female) (B) Resistance Max.

1 z 4 Grounding fault in wiring harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C01 (female) (14) – S12 (female) (B) and chassis ground Resistance Min. 1 Mz 5 Hot short in wiring har- ness (Contact with 24V circuit) aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. Wiring harness between C01 (female) (22) – S12 (female) (C) and chassis ground Voltage Max. 5 V Wiring harness between C01 (female) (14) – S12 (female) (B) and chassis ground Voltage Max.

5 V 6 Defective work equip- ment and pump con- troller If causes 1 – 5 are not detected, work equipment and pump controller may be defective. (Since trouble is in system, troubleshooting cannot be car- ried out.)