SEN02090-00 40 Troubleshooting Failure code [7REPKA] Disconnection in feeder OFF switch 1 34 BR380JG-1E0 User code Failure code Trouble Disconnection in feeder OFF switch (Work equipment and pump controller (work equipment control) system) — 7REPKA Contents of trouble • Input signal circuit for the grizzly feeder OFF switch is opened (disconnected from ground circuit) within 1 second after the engine starting switch ON. Action of controller • Turns all the output OFF for 1 second after turning the engine starting switch ON. • Turns OFF the output to feeder normal rotation EPC. • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF.
Problem that appears on machine • Feeder does not work even if grizzly feeder start switch is pressed. • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • Input state (ON/OFF) of the feeder OFF switch can be checked with the monitoring function (Code: 25000, Switch Input 0) • The failure history is recorded. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective feeder OFF switch aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. B72C (male) Grizzly feeder OFF switch Resistance Between (1) and (2) ON Min.
1 Mz OFF Max. 1 z 2 Disconnection in wiring harness (Disconnec- tion in wiring or defec- tive contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (20) – B72C (female) (2) Resistance Max. 1 z Wiring harness between B72C (female) (1) – chassis ground Resistance Max. 1 z 3 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C03 (female) Resistance Between (20) and chassis ground Max. 1 z