SEN02090-00 40 Troubleshooting Failure code [7RESKB] Short circuit in one-touch start switch 1 36 BR380JG-1E0 User code Failure code Trouble Short circuit in one-touch start switch (Work equipment and pump controller (work equipment control) system) — 7RESKB Contents of trouble • Input signal circuit for the one-touch start switch or work equipment start switch is closed (connected to ground circuit) within 1 second after the starting switch ON. Action of controller • Turns all the output OFF for 1 second after turning the engine starting switch ON. • Turns OFF the output related to one-touch start switch.
(Primary conveyor, magnetic separator, muck discharge conveyor, crusher, feeder) • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF. Problem that appears on machine • Machine does not work even if the one-touch start switch is pressed. • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • Input state (ON/OFF) of the one-touch start switch can be checked with monitoring function (Code: 25003, Switch Input 3) • The failure history is recorded.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective one-touch start switch aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. B71G (male) Work equipment starting switch (One-touch stop switch) Resistance Between (1) and (2) ON Max. 1 z OFF Min. 1 Mz 2 Grounding fault in wir- ing harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C02 (female) (16) – A20 – A44 – A33 (female) (11) and chassis ground Resistance Min.
1 Mz Between wiring harness C02 (female) (16) – A20 (female) (6) – radio controller switch, and chassis ground Resistance Min. 1 Mz 3 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C02 (male) One-touch start switch Resistance Between (16) and chas- sis ground ON Max. 1 z OFF Min. 1 Mz