Kaiyi BR380JG-1E0 — FAILURE CODE [7RF3KY] SHORT CIRCUIT IN CRUSHER REVERSE EPC VALVE

40 Troubleshooting SEN02090-00 Failure code [7RF3KY] Short circuit in crusher reverse EPC valve 1 Circuit diagram related to crusher reverse EPC solenoid BR380JG-1E0 45 User code Failure code Trouble Short circuit in crusher reverse EPC valve (Work equipment and pump controller (work equipment control) system) — 7RF3KY Contents o trouble f • Hot short circuit is detected when EPC valve solenoid for crusher reverse rotation is not driven. Action of controller • None in particular. • If the cause of the failure disappears, the system resets itself. Problem th appears o machine at • The crusher does not stop operating in reverse.

n • When this trouble is detected, the horn sounds (3 times intermittently). Related information • The failure history is recorded. Possible causes an standard val in normal sta Cause Hot short with wiring 1 harness (Contact with d 24-V circuit) ue te Defective work equip- 2 ment and pump con- troller Standard value in normal state/Remarks on troubleshooting aPrepare with engine starting switch OFF, then turn starting switch ON and carry out troubleshooting. Between wiring harness between C03 (female) (36) – A01 – V01 (female) (2) and chassis ground Voltage Max. 1 V aIf cause 1 is not detected, work equipment and pump controller may be defective.

(Since trouble is in system, troubleshooting cannot be carried out.)