SEN02091-00 40 Troubleshooting Failure code [7RFHKY] Short circuit in conveyor forward relay 1 16 BR380JG-1E0 User code Failure code Trouble Short circuit in conveyor forward relay (Work equipment and pump controller (work equipment control) system) — 7RFHKY Contents of trouble • When the conveyor forward relay is not driven, hot short of the circuit (contact with 24 V circuit) is detected. Action of controller • None in particular. Problem that appears on machine • The conveyor forward rotation does not stop. (If it does not stop, press the engine stop switch or turn OFF the engine starting switch.) • Horn sounds (three intermittent sounding) upon detecting a failure.
Related information • The drive state (ON/OFF) of the conveyor forward relay solenoid can be checked with the monitor- ing function (Code: 25602, Relay Drive 1) • This failure code is generated when the primary (coil side) of magnetic separator relay has failed. A failure of the secondary (contact side) cannot be detected with this code. • The failure history is recorded. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective conveyor for- ward rotation relay (Internal defect) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON.
R16 (male) Resistance Between (1) and (2) 100 – 500 z 2 Hot short in wiring har- ness (Contact with 24V circuit) aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting Wiring harness between C03 (female) (5) – R16 (female) (1) and chassis ground Voltage Max. 1 V 3 Defective work equip- ment and pump controller aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. C03 (female) Voltage Between (5) and chassis ground Max. 1 V