SEN02091-00 40 Troubleshooting Failure code [7RFMKZ] Disconnection or short circuit in abnormal pressure relay 1 28 BR380JG-1E0 User code Failure code Trouble Disconnection or short circuit in abnormal pressure relay (Work equipment and pump controller (work equipment control) system) — 7RFMKZ Contents of trouble • When the abnormal pressure recovery relay circuit is not driven, disconnection or ground short cir- cuit is detected. Action of controller • Turns the output to the abnormal pressure recovery relay circuit OFF. • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF.
Problem that appears on machine • The secondary conveyor, water splay, and vibratory screen do not work, or do not stop automati- cally. (If they do not stop, press the stop switch.) • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • The drive state (ON/OFF) of the abnormal pressure relay can be checked with the monitoring func- tion (Code: 25601, Relay Drive 0) • This failure code is generated when the primary (coil side) of abnormal pressure recovery relay has failed. A failure of the secondary (contact side) of the relay cannot be detected with this code. • The failure history is recorded.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse No. 10 If fuse No. 10 is blown, circuit probably has ground fault (See cause 4). 2 Defective abnormal pressure recovery relay (Internal discon- nection or contact with ground) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. R05 (male) Resistance Between (1) and (2) 100 – 500 z 3 Disconnection in wiring harness (Disconnec- tion in wiring or defec- tive contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON.
Wiring harness between C02 (female) (18) – R05 (female) (2) Resistance Max. 1 z Wiring harness between R05 (female) (1) – B28 No. 10 Resistance Max. 1 z 4 Grounding fault in wir- ing harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C02 (female) (18) – R05 (female) (2) and chassis ground Resistance Min. 1 Mz Wiring harness between C05 (female) (1) – B28 No. 10 and chassis ground Resistance Min.
1 Mz 5 Defective work equip- ment and pump controller aPrepare with engine starting switch OFF and the conveyor at lower position, then carry out troubleshooting without turning engine starting switch ON. C02 (male) Mode selector switch Voltage Between (18) and chassis ground Working mode Max. 1 V Other than working mode 20 – 30 V