Kaiyi BR380JG-1E0 — FAILURE CODE [AB00KE] CHARGE VOLTAGE TOO LOW

SEN02091-00 40 Troubleshooting Failure code [AB00KE] Charge voltage too low 1 56 BR380JG-1E0 User code Failure code Trouble Charge voltage too low (Machine monitor system) — AB00KE Contents of trouble • While the engine is running, the generation signal is not input from the alternator. Action of controller • None in particular. Problem that appears on machine • If the machine is operated as it is, the battery may not be charged. Related information • If the charge level monitor on the machine monitor lights red while the engine is running, this failure code is recorded. • Input from the alternator (ON or OFF) can be checked in the monitoring function. (Code 04300:

Battery Charge Vol.) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective alternator (Insufficient genera- tion) aPrepare with engine starting switch OFF, then start engine and carry out troubleshooting. E12 (male) Engine speed Voltage Between (1) and chassis ground Medium or higher 27.5 – 29.5 V 2 Disconnection in wir- ing harness (Disconnection in wir- ing harness or defec- tive contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between P02 (female) (11) and E12 (female) (1) Resistance Max.

1 z 3 Short circuit with chas- sis ground in wiring harness (Contact with ground circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Between wiring harness between P02 (female) (11) and E12 (female) (1) and chassis ground Resistance Min. 1 Mz 4 Defective machine monitor aPrepare with engine starting switch OFF, then start engine and carry out troubleshooting. P02 Engine speed Voltage Between (11) and chassis ground Medium or higher 27.5 – 29.5 V