SEN02092-00 40 Troubleshooting Failure code [B@BCZK] Radiator coolant level reduction 1 8 BR380JG-1E0 User code Failure code Trouble Radiator coolant level reduction (Machine monitor system) — B@BCZK Contents of trouble • While the engine is running, the signal circuit of the radiator coolant level switch is opened (discon- nected from the chassis ground). Action of controller • None in particular. Problem that appears on machine • If the machine is operated as it is, the engine may overheat. Relative information • If radiator coolant level caution symbol appears on the machine monitor while the engine is run- ning, this failure code will be recorded.
• Input from the radiator coolant level switch (ON/OFF) can be checked in the monitoring function. (Code 04500: Monitor Input 1) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Lowering of radiator coolant level (When system is nor- mal) Check the coolant level in the radiator sub tank. If it is low, add coolant. (If this trouble occurs frequently, find the cause.) 2 Defective radiator coolant level switch (Internal disconnec- tion) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. S16 (male) Radiator coolant level Resistance Between (1) and (2) Normal Max.
1 z Low Min. 1 Mz 3 Disconnection in wiring harness (Disconnection in wir- ing harness or defec- tive contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Between wiring harness between P02 (female) (3) and S16 (female) (1) and chassis ground Resistance Max. 1 z Between wiring harness between S16 (female) (2) and chassis ground Resistance Max. 1 z 4 Defective machine monitor aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. P02 Radiator coolant level Voltage Between (3) and chassis ground Normal Max. 1 V Low 20 – 30 V