SEN02092-00 40 Troubleshooting Failure code [B@HANS] Hydraulic oil overheat 1 Failure code [CA111] Abnormality in engine controller 1 10 BR380JG-1E0 User code Failure code Trouble Hydraulic oil overheat (Machine monitor system) — B@HANS Contents of trouble • While engine was running, signal circuit of hydraulic oil temperature sensor detected overheating of hydraulic oil (above about 102°C). Action of controller • Displays hydraulic oil temperature monitor with red on machine monitor. • If cause of failure disappears, system resets itself. Problem that appears on machine • If machine is operated as it is, engine may be seized.
Related information • Hydraulic oil temperature can be checked with monitoring function (Code: 04401, Hydr. Oil Temperature) • Method of reproducing failure code: Start engine. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Overheating of hydrau- lic oil (when system is normal) Hydraulic oil may be overheating. Check it and remove cause if it is over- heating. 2 Defective hydraulic oil temperature gauge system If cause 1 is not detected, hydraulic oil temperature gauge system may be defective. Carry out troubleshooting for “E-13 Hydraulic oil temperature gauge does not work normally” in E-mode.
User code Failure code Trouble Abnormality in engine controller (Engine controller system) E10 CA111 Contents of trouble • Memory or power supply circuit in engine controller is defective. Action of controller • None in particular. Problem that appears on machine • Engine does not start. Related information Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective engine controller Engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)