Kaiyi BR380JG-1E0 — FAILURE CODE [CA145] COOLANT TEMPERATURE SENSOR TOO LOW

SEN02092-00 40 Troubleshooting Failure code [CA145] Coolant temperature sensor too low 1 22 BR380JG-1E0 User code Failure code Trouble Coolant temperature sensor too low (Engine controller system) E15 CA145 Contents of trouble • Signal circuit of coolant temperature sensor detected low voltage. Action of controller • Fixes coolant temperature value and continues operation. Problem that appears on machine • Exhaust gas becomes white. • Overheat prevention function does not work. Related information • Signal voltage of coolant temperature sensor can be checked with monitoring function. (Code: 04105, Eng. Water Temp. Vol. Lo) • Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective coolant tem- perature sensor aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. COOLANT TEMP (male) Resistance Between (A) – (B) 0.18 – 160 kz Between (B) – chassis ground Min. 100 kz 2 Ground fault in wiring harness (Short circuit with GND circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between CE01 (female) (15) – COOLANT TEMP (female) (B) and chassis ground Resistance Min.

100 kz 3 Short circuit in wiring harness (with another wiring harness) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between CE01 (female) (15) – each of CE01 (female) pins (With all wiring har- ness connectors disconnected) Resistance Min. 100 kz 4 Defective wiring har- ness connector Connecting parts between coolant temperature sensor – engine wiring harness – engine controller may be defective. Check them directly.

• Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 5 Defective engine controller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. CE01 (male) Resistance Between (15) – (38) 0.18 – 160 kz Between (15) – chassis ground Min. 100 kz