Kaiyi BR380JG-1E0 — FAILURE CODE [CA154] CHARGE TEMPERATURE SENSOR TOO LOW

SEN02092-00 40 Troubleshooting Failure code [CA154] Charge temperature sensor too low 1 26 BR380JG-1E0 User code Failure code Trouble Charge temperature sensor too low (Engine controller system) E15 CA154 Contents of trouble • Temperature signal circuit of boost pressure/temperature sensor detected low voltage. Action of controller • Fixes charge temperature value and continues operation. Problem that appears on machine • Exhaust gas becomes white. • Engine protection function based on boost temperature does not work Related information • Signal voltage on boost temperature side of boost pressure/temperature sensor can be checked with monitoring function. (Code:

18501, Charge Temp Sens Volt) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective boost pres- sure/temperature sen- sor [temperature signal system] aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. BOOST PRESS & IMT (male) Resistance Between (3) – (4) 0.18 – 160 kz Between (3) – chassis ground Min. 100 kz 2 Ground fault in wiring harness (Short circuit with GND circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON.

Wiring harness between CE01 (female) (23) – BOOST PRESS & IMT (female) (3) Resistance Min. 100 kz 3 Short circuit in wiring harness (with another wiring harness) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between CE01 (female) (23) – each of CE01 (female) pins (With all wiring har- ness connectors disconnected) Resistance Min. 100 kz 4 Defective wiring har- ness connector Connecting parts between boost pressure/temperature sensor – engine wiring harness – engine controller may be defective. Check them directly.

• Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 5 Defective engine controller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. CE01 (male) Resistance Between (23) – (47) 0.18 – 160 kz Between (23) – chassis ground Min. 100 kz