SEN02092-00 40 Troubleshooting Failure code [CA187] Sensor power source 2 too low 1 30 BR380JG-1E0 User code Failure code Trouble Sensor power source 2 too low (Engine controller system) E15 CA187 Contents of trouble • Low voltage was detected in sensor power supply 2 circuit. Action of controller • Fixes boost pressure value and continues operation. • Fixes charge temperature value and continues operation. • Limits output and continues operation. Problem that appears on machine • Engine output lowers. Related information • Method of reproducing failure code: Turn starting switch ON.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor or wiring harness aDisconnect connector with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. Disconnect sensors and wiring harness at right in order and carry out operation to repro- duce trouble. If “E” of failure code goes off when a sensor or wiring harness is discon- nected, that sensor or wiring harness is defec- tive.
Boost pressure/temper- ature sensor BOOST PRESS & IMT Common rail pressure sensor FUEL RAIL PRESS Bkup sensor CAM SENSOR Engine wiring harness CE01 2 Defective wiring har- ness connector Connecting parts between each sensor – engine wiring harness – engine controller may be defective. Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 3 Defective engine controller If causes 1 – 2 are not detected, engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)