Kaiyi BR380JG-1E0 — FAILURE CODE [CA352] SENSOR POWER SOURCE 1 TOO LOW

SEN02093-00 40 Troubleshooting Failure code [CA352] Sensor power source 1 too low 1 6 BR380JG-1E0 User code Failure code Trouble Sensor power source 1 too low (Engine controller system) E15 CA352 Contents of trouble • Low voltage was detected in sensor power supply 1 circuit. Action of controller • Fixes ambient pressure value and continues operation. Problem that appears on machine • Engine does not start easily. • Engine output lowers. Related information • Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective sensor or wiring harness aDisconnect connector with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. Disconnect sensor and wiring harness at right in order and carry out operation to reproduce trouble. If “E” of failure code goes off when sensor or wiring har- ness is disconnected, that sensor or wiring harness is defective.

Ambient pressure sensor AMBIENT AIR PRESSURE Engine wiring harness CE01 2 Defective wiring harness connector Connecting parts between ambient pressure sensor – engine wiring har- ness – engine controller may be defective. Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 3 Defective engine controller If causes 1 – 2 are not detected, engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)