Kaiyi BR380JG-1E0 — FAILURE CODE [CA386] SENSOR POWER SOURCE 1 TOO HIGH

SEN02093-00 40 Troubleshooting Failure code [CA386] Sensor power source 1 too high 1 Circuit diagram related to sensor power supply 1 8 BR380JG-1E0 User code Fa ilure code CA386 Trouble Sensor power source 1 too high (Engine controller system) E15 Contents of • H trouble igh voltage was detected in sensor power supply 1 circuit. Action of • F controller ixes ambient pressure value and continues operation. Problem that • E appears on • E machine ngine does not start easily. ngine output lowers. Related • M information ethod of reproducing failure code: Turn starting switch ON.

Possible causes and 1 standard value in normal state 2 Cause Standard value in normal state/Remarks on troubleshooting Defective wiring harness connector Connecting parts between ambient pressure sensor – engine wiring har- ness – engine controller may be defective. Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation Defective engine controller If cause 1 is not detected, engine controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)