Kaiyi BR380JG-1E0 — FAILURE CODE [CA429] WATER DETECTION SENSOR TOO LOW

SEN02093-00 40 Troubleshooting Failure code [CA429] Water detection sensor too low 1 12 BR380JG-1E0 User code Failure code Trouble Water detection sensor too low (Engine controller system) E15 CA429 Contents of trouble • Low voltage was detected in signal circuit of water-in-fuel sensor. Action of controller • None in particular. Problem that appears on machine • Water separator monitor does not display normally. Related information • Condition water-in-fuel sensor signal can be checked with monitoring function. (Code: 18800, Water In Fuel) • Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective water-in-fuel sensor aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. P47 (female) Resistance Between (1) – (2) 10 – 100 kz Between (1) – chassis ground Min. 100 kz 2 Ground fault in wiring harness (Short circuit with GND circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between CE01 (female) (14) – P47 (male) (1) Resistance Min.

100 kz 3 Short circuit in wiring harness (with another wiring harness) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between CE01 (female) (14) – each of CE01 (female) pins (With all wiring har- ness connectors disconnected) Resistance Min. 100 kz 4 Defective wiring harness connector Connecting parts between water-in-fuel sensor – engine wiring harness – engine controller may be defective. Check them directly.

• Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 5 Defective engine controller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. CE01 (male) Resistance Between (14) – (47) 10 – 100 kz Between (14) – chassis ground Min. 100 kz