Kaiyi BR380JG-1E0 — FAILURE CODE [CA757] LOSS OF ALL ENGINE CONTROLLER DATA

SEN02093-00 40 Troubleshooting Failure code [CA757] Loss of all engine controller data 1 32 BR380JG-1E0 User code Failure code Trouble Loss of all engine controller data (Engine controller system) E10 CA757 Contents of trouble • All data in engine controller are lost. Action of controller • None in particular. Problem that appears on machine • Engine may stop and may not be started again. • Monitoring function of machine monitor (engine controller system) may not work normally. Related information • Method of reproducing failure code: Turn starting switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defect in related sys- tem If another failure code is displayed, carry out troubleshooting for it. 2 Looseness or corro- sion of battery terminal Battery terminal may be loosened or corroded. Check it directly. 3 Low battery voltage aPrepare with starting switch OFF, then keep starting switch OFF and start engine and carry out troubleshooting in each case. Battery (1 piece) Starting switch Voltage Between (+) – (–) ter- minals OFF Min. 12 V START Min. 6.2 V 4 Defective fuse No. 19 If fuse is broken, circuit probably has ground fault.

5 Defective relay for engine controller power supply aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. Replace relay (R21, R22) for engine controller with another relay and per- form reproducing operation. If “E” of failure code goes off at this time, replaced relay is defective. 6 Disconnection in wiring harness (Disconnec- tion in wiring or defec- tive contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between B28 No.3 – R21, R22 (female) (3) Resistance Max.

10 z Wiring harness between R21, R22 (female) (5) – CE03 (female) (3) Resistance Max. 10 z Wiring harness between CE03 (female) (1) – chassis ground (T27) Resistance Max. 10 z 7 Defective wiring harness connector Connecting parts between fuse No.3 – machine wiring harness – engine controller may be defective. Check them directly. • Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation 8 Defective engine controller aPrepare with engine starting switch OFF, then turn engine starting switch ON and start engine and carry out troubleshooting in each case.

CE03 (male) Starting switch Voltage Between (3) – (1) ON Min. 24 V START Min. 12 V