Kaiyi BR380JG-1E0 — FAILURE CODE [CA1633] CAN COMMUNICATION ERROR (ENGINE CONTROLLER)

40 Troubleshooting SEN02093-00 Circuit diagram related to CAN communication BR380JG-1E0 37 Poss cause standard in norma Cause Defective CAN termi- ible nal resistance (Inter- s and 4 nal short circuit or value disconnection) l state Defective engine 5 controller Standard value in normal state/Remarks on troubleshooting Defective CAN termi- nal resistance (Inter- nal short circuit or disconnection) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. K02 (male), P03 (male) Resistance Between (A) – (B) 120 ± 12 z Resistance 120 ± 12 z Defective engine controller If causes 1 – 4 are not detected, engine controller may be defective.

(Since trouble is in system, troubleshooting cannot be carried out.)