Kaiyi BR380JG-1E0 — FAILURE CODE [D162KY] SHORT CIRCUIT IN HORN RELAY

SEN02094-00 40 Troubleshooting Failure code [D162KY] Short circuit in horn relay 1 4 BR380JG-1E0 User code Failure code Trouble Short circuit in horn relay (Work equipment and pump controller (work equipment control) system) — D162KY Contents of trouble • When the horn relay drive circuit is driven, hot short of the circuit (contact with 24 V circuit) is detected. Action of controller • Turns the output to the horn relay circuit OFF. • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF. Problem that appears on machine • Horn does not sound in the following situations.

• When abnormality in mechanical system (abnormal engine coolant etc.) occurs • When all functions of work equipment stops due to overload to the equipment • When electrical system is failed Related information • Horn relay drive state (ON/OFF) can be checked with monitoring function (Code: 25601, Relay Drive 0) • Since short circuit is detected while the horn output is turned ON, be sure to turn the horn output ON when checking for reproduction of the failure after repair. • The failure history is recorded.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective horn relay (Internal short circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Horn relay R04 (male) Continuity/Resistance Between (1) and (2) 100 – 500 z 2 Defective resistance (Internal short circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON.

A29 (male) Resistance Between (2) and (7) 1.8 – 2.6 kz 3 Hot short in wiring har- ness (Contact with 24 V circuit) aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. Between wiring harness between C02 (female) (19) – D01 (female) (1) and chassis ground Voltage Max. 5.7 V 4 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. Short C02 (female) (19) with chassis ground Horn Sounds