Kaiyi BR380JG-1E0 — FAILURE CODE [DA22KK] SOLENOID POWER SOURCE TOO LOW

SEN02094-00 40 Troubleshooting Failure code [DA22KK] Solenoid power source too low 1 8 BR380JG-1E0 User code Failure code Trouble Solenoid power source too low (Work equipment and pump controller (pump control) system) E0E DA22KK Contents of trouble • Solenoid power supply voltage of controller is below 20 V. Action of controller • While this failure code is displayed, detection of failure codes (disconnection/short circuit) of all the solenoid systems is stopped. • Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF. Problem that appears on machine • Since no solenoid valve is driven normally, machine does not operate normally.

• When the failure is detected, the horn sounds (3 times intermittently) Related information • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fusible link E07 or fuse No. 6 If fusible link or fuse is broken, circuit probably has ground fault. (See Cause 3.) 2 Disconnection in wiring harness (Disconnec- tion in wiring or defec- tive contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (2), (12), (22) – B28 No. 6 Resistance Max.

1 z Wiring harness between B28 No. 6 – E07 (male) (2) Resistance Max. 1 z Wiring harness between E07 (male) (1) – T09 Resistance Max. 1 z 3 Ground fault in wiring harness (Short circuit with GND circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (2), (12), (22) – B28 No. 6 Resistance Min. 1 Mz Wiring harness between B28 No. 6 – E07 (male) (2), – circuit branch end Resistance Min. 1 Mz Wiring harness between E07 (male) (1) – T09 Resistance Min.

1 Mz 4 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. C03 (female) Voltage Between C03 (male) (2), (12), (22) – (13), (21), (23), (31), (32), (33), 20 – 30 V