SEN02094-00 40 Troubleshooting Failure code [DDA6KA] Disconnection in engine stop switch 1 20 BR380JG-1E0 User code Failure code Trouble Disconnection in engine stop switch (Work equipment and pump controller (work equipment control) system) — DDA6KA Contents of trouble • The engine stop switch input signal circuit is opened (disconnected from the terminal ACC) in 1 sec- ond after the engine starting switch is turned ON. Action of controller • None in particular (The engine stop switch is kept depressed). • Even if the cause of the failure disappears, the system does not reset itself until the starting switch is turned OFF.
Problem that appears on machine • When this trouble is detected, the horn sounds (3 times intermittently). Related information • The input state (ON/OFF) of the engine stop switch can be checked with monitoring function (Code: 25003, Switch Input 3). • The failure history is recorded. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective engine stop switch aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Between B76B (female) (1) and B76A (male) (1) Engine stop switch Resistance ON Min. 1 Mz OFF Max.
1 z 2 Disconnection in wiring harness (Disconnec- tion in wiring harness or defective contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C01 (female) (18) and B76B (male) (1) Resistance Max. 1 z Wiring harness between B76A (female) (1) and terminal ACC Resistance Max. 1 z 3 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C01 (female) Resistance Between (18) and chassis ground Max. 1 z