Kaiyi BR380JG-1E0 — FAILURE CODE [DHPAMA] ABNORMALITY IN F PUMP PRESSURE SENSOR

SEN02094-00 40 Troubleshooting Failure code [DHPAMA] Abnormality in F pump pressure sensor 1 24 BR380JG-1E0 User code Failure code Trouble Abnormality in F pump pressure sensor (Work equipment and pump controller (pump control) system) — DHPAMA Contents of trouble • Signal voltage of F pump pressure sensor circuit is below 0.3 V or above 4.5 V. Action of controller • Fixes F pump pressure at 0 MPa {0 kg/cm2} and continues control. • If cause of failure disappears, system resets itself. Problem that appears on machine • Feeder automatic stop function does not work when overload on the crusher is detected.

• Overheat prevention function does not work properly (machine will overheat more easily). Related information aIf 5V circuit (3) and ground circuit (1) of pressure sensor are connected inversely, pressure sensor will be broken. Accordingly, take extreme care when checking. • F pump pressure can be checked with monitoring function. (Code: 01100, F Pump Pressure) • Method of reproducing failure code: Turn engine starting switch ON or start engine. • The failure history is recorded.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective 5V sensor power supply 1 system aIf failure code [DA25KP] is also displayed, carry out troubleshooting for it first. 2 Defective F pump pressure sensor (Internal defect) aPrepare with engine starting switch OFF, then turn engine starting switch ON or start engine and carry out troubleshooting in each case. S10 Voltage Between (3) – (1) Power supply 4.5 – 5.5 V Between (2) – (1) Signal 0.3 – 4.5 V If voltage is abnormal, replace F pump pressure sensor with R pump pres- sure sensor and check failure code.

(If “E” of failure code goes off at this time, F pump pressure sensor is defective.) 3 Disconnection in wiring harness (Disconnec- tion in wiring or defec- tive contact in connector) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C01 (female) (4), (10) – J02 – S10 (female) (1) Resistance Max. 1 z Wiring harness between C01 (female) (8) – S10 (female) (2) Resistance Max. 1 z Wiring harness between C01 (female) (22) – J03 – S10 (female) (3) Resistance Max.

1 z 4 Ground fault in wiring harness (Short circuit with GND circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C01 (female) (8) – S10 (female) (2) Resistance Min. 1 Mz 5 Hot short (Short circuit with 24V circuit) in wir- ing harness aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. Wiring harness between C01 (female) (8) – S10 (female) (2) Voltage Max. 1 V 6 Defective work equip- ment and pump con- troller If causes 1 – 5 are not detected, work equipment and pump controller may be defective.

(Since trouble is in system, troubleshooting cannot be car- ried out.)