Kaiyi BR380JG-1E0 — FAILURE CODE [DUB0KY] SHORT CIRCUIT IN BEACON SOLID STATE RELAY

SEN02094-00 40 Troubleshooting Failure code [DUB0KY] Short circuit in beacon solid state relay 1 28 BR380JG-1E0 User code Failure code Trouble Short circuit in beacon solid state relay (Work equipment and pump controller (work equipment control) system) — DUB0KY Contents of trouble • When the rotary lamp relay is driven, hot short circuit (contact with 24 V circuit) is detected. Action of controller • Turns electric current to the rotary lamp relay circuit OFF. • Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF. Problem that appears on machine • Rotary lamp does not light up.

• Horn sounds (three intermittent sounding) upon detecting a failure. Related information • Drive state (ON/OFF) of the rotary lamp SSR can be checked with monitoring function. (Code: 25601, Relay Drive 0) • Since short circuit is detected when output of the rotary lamp is ON, turn the output ON for reproduc- tion check after recovery. • Since this failure code detects the abnormality of the primary side (input side) of rotary lamp SSR (solid state relay), the secondary side (load side) cannot be detected. • The failure history is recorded.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective resistance (Internal short circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Between A29 (male) (4) and (5) Resistance 2 – 2.4 kz Between A29 (male) (3) and (6) Resistance 2 – 2.4 kz 2 Hot short in wiring harness (Contact with 24 V circuit) aPrepare with engine starting switch OFF and with A29 and R17 discon- nected, then turn engine starting switch ON and carry out troubleshoot- ing. Between C02 (female) (9) and chassis ground Voltage Max.

1 V 3 Defective work equip- ment and pump con- troller aPrepare with engine starting switch OFF and with C02 (female) (9) dis- connected, then turn engine starting switch ON and carry out trouble- shooting. This failure code is not displayed in machine monitor. 4 Defective rotary lamp relay (Internal defect) If the above items 1 – 3 are normal, the work equipment, pump controller or beacon lamp relay may be defective.