Kaiyi BR380JG-1E0 — FAILURE CODE [DXE0KA] DISCONNECTION IN LS-EPC SOLENOID

40 Troubleshooting SEN02094-00 Failure code [DXE0KA] Disconnection in LS-EPC solenoid 1 Related electrical circuit diagram BR380JG-1E0 35 User code Failure code Trouble Disconnection in LS-EPC solenoid (Work equipment and pump controller (pump control) system) — DXE0KA Contents o trouble f • When the LS-EPC solenoid is driven, disconnection of the circuit is detected. Action of controller • None in particular. (Since no electric current flows, solenoid does not operate.) • If cause of failure disappears, system resets itself. Problem th appears o machine at • Travel Hi/Lo cannot be switched over, or work equipment speed becomes high.

n (Set pressure for LS valve cannot be controlled.) • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • The failure history is recorded. • LS-EPC electric current value can be checked with the monitoring function. (Code: 01500, LS-EPC Sol.

Curr.) Possible causes an standard val in normal sta Cause Defective LS-EPC 1 solenoid (Internal dis- connection) Disconnection in wiring d harness (Disconnec- ue 2 tion or defective con- te tact in connector) Defective work equip- 3 ment and pump con- troller Standard value in normal state/Remarks on troubleshooting aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. V05 (male) Resistance Between (1) and (2) 7 – 14 z aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (6) – V05 (female) (1) Resista nce Max.

1 z Wiring harness between C03 (female) (3) – V05 (female) (2) Resista nce Max. 1 z aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C03 (female) Resistance Between (6) and (3) 7 – 14 z