Kaiyi BR380JG-1E0 — E-6 THE RED MARK OF EMERGENCY STOP IS INDICATED JUST AFTER THE ENGINE IS STARTED

40 Troubleshooting SEN02095-00 BR380JG-1E0 17 Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 3 Disconnection in wiring harness (Disconnec- tion in wiring harness or defective contact in connector) (A: When optional equipment is installed) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between B28 (6) – A06 (6) – B92D (1) – B91D (1) – A36 (female) (6) Resistance Max. 1 z Wiring harness between A36 (female) (5) – B92B (1) – B91B (1) – A36 (female) (4) Resistance Max.

1 z Wiring harness between A36 (female) (3) – B92A (1) – B91A (1) – A36 (female) (2) Resistance Max. 1 z Wiring harness between A36 (female) (1) – B91C (1) – B92C (1) – A08 (4) – A04 (5) – A10A (9) – B74B (1) /AB93F (1) – B75B (1) / AB94F (1) – A10A (male) (11) Resistance Max. 1 z AWiring harness between A10AB (female) (11) – B91J (1) – B92J (1) – A10AA (male) (11) Resistance Max. 1 z Wiring harness between A10A (female) (11) – A34 (female) (11) Resistance Max. 1 z Wiring harness between A34 (female) (2) – B91E (1) – B92E (1) – A34 (female) (3) Resistance Max. 1 z Wiring harness between A34 (female) (4) – A10B – A04 (3) – B75A (1) – B74A (1) – R23 (female) (3) Resistance Max.

1 z AWiring harness between A34 (female) (4) – A10B (4) – A37 (1) – B94G (1) – B93G (1) – B94H (1) – B93H (1) – A38 (male) (1) Resistance Max. 1 z AWiring harness between A38 (male) (2) – A37 (2) – A10B (male) (6) Resistance Max. 1 z Wiring harness between R23 (female) (5) – C01 (female) (24) Resistance Max. 1 z Wiring harness between R28 (10) – A04 (9) – S24 – A04 (7) – R23 (female) (1) Resistance Max. 1 z Wiring harness between R23 (female) (2) – chassis ground Resistance Max. 1 z Wiring harness between A36 (male) (6) – A36 (male) (5) Resistance Max. 1 z Wiring harness between A36 (male) (4) – A36 (male) (3) Resistance Max.

1 z Wiring harness between A36 (male) (2) – A36 (male) (1) Resistance Max. 1 z Wiring harness between A34 (male) (1) – A36 (male) (2) Resistance Max. 1 z Wiring harness between A34 (male) (3) – A34 (male) (4) Resistance Max. 1 z Wiring harness between A10B (male) (4) – A10B (male) (6) Resistance Max. 1 z AWiring harness between A38 (female) (1) – A38 (female) (2) Resistance Max. 1 z 4 Defective controller aPrepare with starting switch OFF (Check that all the emergency stop switches have cancelled), then turn starting switch ON and carry out troubleshooting. C01 Voltage Between (24) – chassis ground 20 – 30 V