SEN02095-00 40 Troubleshooting E-18 Travel cannot be controlled by radio control 1 36 BR380JG-1E0 Trouble • Travel cannot be controlled by radio control. Relative information • Radio control system is an optional specification. • (1) Start the engine and turn the radio control selector switch to the remote control position, (2) Turn the power switch of the radio control transmitter ON, and (3) Check that the radio wave from the radio control transmitter is received by the receiver (The antenna of the receiver is built in). If the radio wave is received, the yellow radio control lamp lights up and the machine can be radio- controlled.
• The machine may be interlocked by either the mode selector switch, travel speed selection or con- veyor height. (See Troubleshooting E-17.) • The travel switch of the radio controller works under the below conditions. (1) When the travel operation switch is pressed within about 30 seconds after the travel mode selector switch is pressed. (2) When the travel operation switch is pressed again within about 30 seconds after the switch is released from (1). • If any of (1), (2), and (3) above is not established (If the radio control lamp does not light up), the machine cannot be radio-controlled.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse No. 13 If the fuse is broken, the circuit probably has a grounding fault. 2 Defective radio control power supply circuit (Disconnection or short circuit) aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Receiver connector A33 (female) Radio control selector switch Voltage Between (1) – (2) Panel Max. 1 V Remote control 20 – 30 V If the above power supply circuit is found to be defective, carry out troubleshooting for 2-1 to 2-4 below.
2-1 Defective radio controller selec- tor switch (Inter- nal disconnection or short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Radio controller selec- tor switch B50 (male) Radio controller selec- tor switch Resistance (2) – (4) Panel Min. 1 Mz Remote control Max. 1 z 2-2 Disconnection in wiring harness (Disconnection or defective contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Between B28 (13) – A20 (1) – A44 (1) – A33 (female) (1) Resistance Max. 1 z Between B50 (female) (2) – A20 (2) – A44 (2) – A33 (female) (2) Resistance Max.
1 z 2-3 Grounding fault in wiring harness (Contact with ground circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Between wiring harness B28 (13) – A20 (1) – A44 (1) – A33 (female) (1) and chassis ground Resistance Min. 1 Mz 2-4 Hot short circuit in wiring harness (Contact with 24V circuit) (Troubleshooting with radio control- ler selector switch turns to Panel.) aPrepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Between wiring harness B50 (female) (2) – A20 (2) – A44 (2) – A33 (female) (2) and chassis ground Voltage Max. 1 V