Kaiyi BR380JG-1E0 — E-20 ONE-TOUCH START, STOP SWITCH CANNOT BE OPERATED BY RADIO CONTROL

40 Troubleshooting SEN02095-00 BR380JG-1E0 45 Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 3 Disconnection in wiring harness (Disconnection in wir- ing harness or defec- tive contact in connector) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between A33 (female) (3) – A45 – A32 (female) (1) Resistance Max. 1 z Wiring harness between A33 (female) (3) – chas- sis ground Resistance Max. 1 z Wiring harness between A33 (female) (11) – A44 (6) – A20 (6) – C02 (female) (16) Resistance Max.

1 z Wiring harness between A33 (female) (14) – RR02 (female) (2) Resistance Max. 1 z Wiring harness between A33 (female) (1) – RR02 (female) (1), RR04 (female) (1) Resistance Max. 1 z Wiring harness between RR02 (female) (6) – A44 (8) – A20 (8) – C02 (female) (6) Resistance Max. 1 z Wiring harness between RR02 (female) (3) – chassis ground Resistance Max. 1 z Wiring harness between A33 (female) (12) – A44 (10) – A20 (10) – C03 (female) (9) Resistance Max. 1 z Wiring harness between B50 (female) (2) – C03 (female) (39) Resistance Max. 1 z Wiring harness between A33 (female) (16) – RR04 (female) (2) Resistance Max.

1 z 4 Defective relay (Internal disconnection or short circuit) aPrepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. RR02 (male) Resistance Between (1) – (2) 250 – 350 z Between (3) – (6) Max. 1 z 5 When controller detects failure of related section If any of the following errors is displayed in the electrical system errors on the monitor, see the troubleshooting for it. • Short circuit in one-touch start switch [7RESKB] • Disconnection in one-touch stop switch [7RETKA] 6 Defective transmitter or receiver If all the results of above checks 1 – 5 are normal, the transmitter or receiver is defective.