376 Proceed as follows: – Connect a wire between GND and pin 7. – Connect another wire between data out and pin 3. – The position of the third wire varies from printer to printer. – For Qume printers connect CTS to pin 20. – If that doesn’t work then try CTS to pin 4. If you require a more complete RS232 connection try the following: – Data in to pin 2 (transmit data). – Data out to pin 3 (receive data). – CTS to pin 4 (clear to send). – RTS to pin 5 (request to send). – 5 GND to pin 7 (signal ground). Telling the computer whether you are using a serial or parallel printer *FX5 is used to inform the computer whether it is to send printer output to the parallel or serial port. Type:
*FX5,1 if you are using a parallel printer *FX5,4 if you are using the Econet printer *FX5,2 if you are using a serial printer The computer defaults to (assumes unless you tell it otherwise, that you are using) a parallel printer. If you have selected a serial printer then you will have to set the baud rate to match that on the printer. The default setting is 9600 baud but many printers run at other rates. Select one of *FX 8,1 75 baud *FX 8,2 150 baud *FX 8,3 300 baud *FX 8,4 1200 baud *FX 8,5 2400 baud *FX 8,6 4800 baud *FX 8,7 9600 baud *FX 8,8 19200 baud (this rate is not guaranteed)