419 OSBYTE call with A=&8B (139) File options This call is directly equivalent to *OPT and it controls the computer’s response to errors during file operations such as LOAD and SAVE . See chapter 35 for more details. For example, with the cassette filing system *FX139,1,0 would issue no messages during file operations. *FX139,2,2 would make the computer abort if any error were detected. *FX139,3,5 would result in 0.5 second inter-block gaps. On entry X contains the option number and Y contains the particular selected option. Thus LDA #139 LDX #1 LDY #0 JSR &FFF4 would ensure that no error messages were issued during file operations.

OSBYTE call with A=&8C (140) Tape speed This call is directly equivalent to *TAPE which selects the cassette file system and the baud rate to be used. On entry X contains a number to set the baud rate. X=0 Default rate (1200 baud) X=3 300 baud X=12 1200 baud This call is functionally equivalent to *TV . The contents of the X register are used to control the vertical position of the screen display. For example, setting X=2 would move the display two text lines up the screen. Setting X=253 would move the display three lines down the screen. The contents of Y should be either 0 or 1 on entry. Y=0 gives an interlaced display and Y=1 gives a non-interlaced display.

Note that the offset and interlace mode selected only come into effect at the next MODE change. The values set stay in force until a hard reset. Interlace is off on power up. OSBYTE call with A=&90 (144) TV