beckhoff TF5200 | TwinCAT 3 CNC — 5 Use of the dll in a test GUI

Use of the dll in a test GUI 5 Use of the dll in a test GUI isg-encrypt-x*.dll in the ISG Crypter application Fig. 3: Overview of how to use the ISG Crypter Description of highlighted elements: CNC Program encryption 16 Version: 1.32 TF5200 | TwinCAT 3 CNC Index Meaning Description 1 File list This lists all the files to be encrypted. The first column contains the file names of the source; the second column specifies the target file names; the third column defines the size. 2 Add files Opens a dialog box to add one or more files to the file list. 3 Add folder Opens a dialog box to add all the files in a folder (and all subfolders) to the file list.

4 Load file lists Opens a dialog box to load one or more file lists previously saved. 5 Save file list Saves the current file list. 6 Remove selected Removes selected entries from the file list. 7 Remove all Removes all entries from the file list. 8 Key The secret key used for encryption. The identical key must then be transferred to the CNC later, e.g. via the associated CNC object. 9 Output folder This lets you specify a folder to save the encrypted files in. If this field remains empty, each encrypted file is stored in the folder of the associated source file. 10 File extension Specifies the file extension used for encrypted files. 11 ENCRYPT Starts encryption.

12 Log output Displays information, warnings and errors. 13 Language Changes the language of GUI elements. 14 Online documentation Link to ISG Online Documentation for encryption.