IP67 Charger — 5.2. Wiring

Blue Smart IP67 Charger 3. Connect the DC power cabling to the battery/batteries or DC system distribution bus - follow the instructions relevant to the installation type. A. For hardwired installations, or when charging a battery outside of a vehicle/installation: i. Ensure that the DC system is shut down (all DC loads and charge sources off/isolated) prior to disconnection of any existing battery / DC system distribution bus cabling and connection of the charger to the battery terminals / DC system distribution bus. ii.

Connect the positive DC cable (red insulation) to the positive ( + ) terminal and the negative DC cable (black insulation) to the negative ( - ) terminal connection; ensure that the cable connection polarity is correct. iii. Torque all wiring termination hardware to manufacturers torque specifications using a suitable torque wrench and socket / screw driver bit. B. For temporary installations when charging a battery installed within a vehicle, and the negative (-) battery terminal is grounded to the vehicle chassis (conventional): ii.

Then connect the negative DC cable / battery clamp (black insulation) to a suitable grounding point on the vehicle chassis (not directly to the negative battery terminal). i. Connect the positive DC cable / battery clamp (red insulation) directly to the battery positive ( + ) terminal first. iii. When disconnecting the charger, disconnect the DC cables / battery clamps in reverse of the connection order. C. For temporary installations when charging a battery installed within a vehicle, and the positive (+) battery terminal is grounded to the vehicle chassis (unconventional): i.

Connect the negative DC cable / battery clamp (black insulation) directly to the battery negative ( - ) terminal first. ii. Then connect the positive DC cable / battery clamp (red insulation) to a suitable grounding point on the vehicle chassis (not directly to the positive battery terminal). iii. When disconnecting the charger, disconnect the DC cables / battery clamps in reverse of the connection order. 4. Connect the Blue Smart IP67 Charger AC power cable to a mains power outlet; after a short delay the POWER LED will illuminate and the STATUS LED will begin to blink fast.

Example wiring schematics depicting most typical installation configurations are also provided for reference; refer to the 'Installation > Schematics' section for more information. Page 14 Installation