Blue Smart IP67 Charger 4. Select the charge mode and charge current limit most appropriate for the battery type and capacity. To setup using VictronConnect: A. Using a Bluetooth enabled device (mobile phone or tablet), open the VictronConnect app and locate the Blue Smart IP67 Charger in the Device list Local page, then connect to the device (the default PIN code is stated on a label located on the back of the charger, or try 000000 if there is no label). B. Select the Settings icon (gear in the top right corner) to access the Settings page. C. Select the most appropriate integrated charge mode (Normal, Normal + Recondition, High, High + Recondition or Li-ion) from the Charge preset menu.
D. If the maximum rated charge current is excessive, enable low current mode; refer to the 'Setup > Setup using VictronConnect' section for instructions. 5. When the STATUS LED is blinking slowly the charger has moved into absorption stage (bulk stage is complete); the battery will be approximately 80% charged (or >95% for Li-ion batteries) and may be returned into service if required. All settings are stored and will not be lost when the charger is disconnected from mains power or the battery. 6. When the STATUS LED is illuminated the charger has moved into float stage (absorption stage is complete); the battery will be fully (100%) charged and is ready to be returned into service. 7.
When the STATUS LED has turned off the charger has moved into storage mode (float stage is concluded); to maintain the battery at full charge, the battery can be left on continuous charge for an extended duration. 8. To stop charging disconnect the power supply to the AC power cable. Page 3 Quick start guide