Blue Smart IP67 Charger 2. Select User defined from the Battery preset dropdown menu. 3. User defined configuration will now be enabled. 4. Configure the advanced settings as required per battery manufacturers recommendations. The advanced settings (with expert mode disabled) include: A. Battery preset The Battery preset dropdown allows selection from the following options: i. Built-in preset Selection of a standard integrated pre-set (same as the general settings menu) ii. User defined Configuration of user defined charge settings and selection of the last user defined configuration iii.
Select preset Selection from an extended range of integrated battery charging pre-sets, including new user defined charging pre-sets iv. Create preset A new charging preset to be created and saved from user defined settings v. Edit presets An existing preset to be edited and saved B. Maximum charge current The maximum charge current setting allows selection between the default and a significantly reduced charge current limit preset; Maximum or Low (reduced current level varies between models, refer to 'Technical Specifications' section for more information) current. C.
Charge voltage The charge voltage settings enable the voltage setpoint for each charge stage to be independently configured and some charge stages (recondition and float) to be disabled or enabled. The charge voltage setpoint can be configured for the following charge stages: i. Absorption ii. Float iii. Storage D. Voltage compensation iv. Recondition i. Temperature compensation The temperature compensation setting enables the charge voltage temperature compensation coefficient to be configured, or temperature compensation to be totally disabled (such as for Li-ion batteries).
The temperature compensation coefficient is specified in mV/°C and applies to the entire battery/battery bank (not per battery cell). Page 58 Advanced Configuration