Topdon — Руководство по эксплуатации BT600 - Батарейный тестер (EN)

5) The test result will appear soon on the tool's display. Figure 4.1.5 Figure 4.1.6 Battery Test Terminology: EN I 16 SETTING RATE 600CCA CCA EXIT ENTER BATTERY TEST GOOD BATTERY HEALTH 100% 638CCA CHARGE 100% 12.67V INTERNAL R 3.57mΩ RATED 600CCA EXIT ENTER HEALTH (SOH) The state of health shows the difference between the battery being tested and a new battery, considering cell aging. The SOH is defni ed according to the maximum battery charge ratio and its capacity. CHARGE (SOC) The state of charge describes the difference between a fully charged battery and the same battery in use. It analyses the remaining quantity of electricity available in the cell.

The SOC is established according to the battery's remaining charge ratio, divided by the maximum charge that the battery can deliver. INTERNAL R (Internal Resistance) The internal resistance is the opposition to the current fol w presented by the cells and the battery itself, generating heat. Its electronic resistance and ionic resistance directly impact this indicator.