Supermicro A+ Server 2021TM-BTRF/BIBXRF — Supermicro A+ Server 2021TM-BTRF/BIBXRF User Manual PDF

A+ SERVER 2021TM-BTRF/BIBXRF User's Manual 2-5 Checking the Serverboard Setup After you install the 2021TM-BTRF/BIBXRF in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made. Accessing the inside of the System Before operating the server for the fi rst time, it is important to remove the protective fi lm covering the top of the chassis, in order to allow for proper ventilation and cooling. Removing the Chassis Cover and Protective Film Remove the two screws which secure the top cover onto the chassis as 1. shown above. Lift the top cover up and off the chassis. 2.

Peel off the protective fi lm covering the top cover and the top of the chassis 3. Check that all ventilation openings on the top cover and the top of the chassis 4. are clear and unobstructed. Checking the Components and Setup You may have one or two processors already installed into the serverboard. 1. Each processor needs its own heat sink. See Chapter 5 for instructions on processor and heat sink installation. Your 2021TM-BTRF/BIBXRF server system may have come with system 2. memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5. If desired, you can install add-on cards to the system. See Chapter 5 for 3.

details on installing PCI add-on cards. Make sure all power and data cables are properly connected and not blocking 4. the chassis airfl ow. Also make sure that no cables are positioned in front of the fans. See Chapter 5 for details on cable connections. 2-8