Supermicro A+ Server 2021TM-BTRF/BIBXRF — Supermicro A+ Server 2021TM-BTRF/BIBXRF User Manual PDF

Chapter 5: Advanced Serverboard Setup Installing a Passive Heatsink Installing the Heatsink Retention Modules Two heatsink retention modules (BKT-0012L) and four screws are included in the retail box. Once installed, these are used to help attach the heatsinks to the CPUs. To install, align the module with the standoffs of the preinstalled CPU backplate and with the four feet on the module contacting the serverboard. Secure the retention module to the backplate with two of the screws provided. See Figure 2-1. Repeat for the second CPU socket. Note: BKT-0012L is included for use with non-Supermicro heatsinks only.

When installing Supermicro heatsinks, only BKT-0011L (the pre-installed CPU backplate) is needed. The BKT-0012L retention module was designed to provide compatibility with clip-and-cam type heatsinks from third parties. Figure 2-1. CPU Heatsink Retention Module Installation Installing the Heatsink The use of active type heatsinks (except for 1U systems) are recommended. Connect the heatsink fans to the appropriate fan headers on the serverboard. To install the heatsinks, please follow the installation instructions included with your heatsink package (not included). 5-7