Siemens — Technical specifications

3RV Motor Starter Protectors/Circuit Breakers up to 100 A General data Footnotes for page 5/16: 1) For 3RV16 voltage transformer circuit breakers see more "Technical specifications" . Footnotes for page 5/17 : 1) Cable lug and busbar connection possible after removing the box terminals. 2) Above +60 °C current reduction. 2) If bars larger than 12 mm x 10 mm are connected, a 3RT19 46-4EA1 terminal cover is needed to comply with the phase clearance. 3) 500 V with molded-plastic enclosure. 4) Terminal compartment IP00 (exception: 3RV10 11-..2. motor starter protectors with Cage Clamp terminals degree of protection IP20).

3) If conductors larger than 25 mm 2 are connected, a 3RT19 46-4EA1 terminal cover is needed to comply with the phase clearance. 5) With appropriate accessories. 4) If two different conductor cross-sections are connected to one clamping point, both cross-sections must lie in the range specified. If identical cross-sections are used, this restriction does not apply. 5) For corresponding 8WA2 803 or 8WA2 880 opening tools see Catalog LV 1, Chapter 5 "Protection Equipment" --> "3RV Motor Starter Protectors up to 100 A" --> "Accessories". 6) With conductor cross-sections of 1 mm 2 an "insulation stop" must be used (see Chapter 3 "Contactors and Contactor Assemblies" --> "Accessories").

17 Siemens · 2009 Conductor cross-sections of main circuit Type 3RV1. 3RV1. 2 3RV1. 3 3RV1. 4/ 3RV17 42 3RV17 21, 3RV18 21 Connection type Screw terminals Screw terminals with box terminal Terminal screw Pozidriv size 2 Pozidriv size 2 4 mm Allen screw Pozidriv size 2 Prescribed tightening torque Nm 0.8 ... 1.2 2 ... 2.5 3 ... 4.5 4 ... 6 2.5 ... 3 Conductor cross-sections (1 or 2 conductors connectable) • Solid mm2 • Finely stranded with end sleeve mm2 • Stranded mm2 • AWG cables, solid or stranded AWG 2 x (0.5 ... 1.5)4), 2 x (0.75 ... 2.5)4) 2 x (1 ... 2.5)4), 2 x (2.5 ... 6)4) 2 x (0.75 ... 16) 2 x (2.5 ... 16) 1 ... 10, max. 2 x 10 2 x (0.5 ... 1.5)4), 2 x (0.75 ... 2.5)4) 2 x (1 ...

2.5)4), 2 x (2.5 ... 6)4) 2 x (0.75 ... 16), 1 x (0.75 ... 25) 2 x (2.5 ... 35), 1 x (2.5 ... 50) 1 ... 16, max. 6 + 16 2 x (0.5 ... 1.5)4), 2 x (0.75 ... 2.5)4) 2 x (1 ... 2.5)4), 2 x (2.5 ... 6)4) 2 x (0.75 ... 25), 1 x (0.75 ... 35) 2 x (10 ... 50), 1 x (10 ... 70) 1.5 ... 25, max. 10 + 25 2 x (18 ... 14) 2 x (14 ... 10) 2 x (18 ... 2), 1 x (18 ... 2) 2 x (10 ... 1/0), 1 x (10 ... 2/0) 2 x (14 ...

10) Ribbon cable conductors (number x width x thickness) mm -- 2 x (6 x 9 x 0.8) -- Removable box terminals1) • With copper bars2) • With cable lugs3) -- -- 18 x 10 -- -- -- Up to 2 x 70 -- Connection type Cage Clamp terminals5)6) Conductor cross-sections (1 or 2 conductors connectable) • Solid mm2 • Finely stranded with end sleeve mm2 • Finely stranded without end sleeve mm2 • AWG cables, solid or stranded AWG Max. external diameter of the conductor insulation mm 2 x (0.25 ... 2.5) -- 2 x (0.25 ... 1.5) -- 2 x (0.25 ... 2.5) -- 2 x (24 ... 14) -- 3.6