Siemens — 3RF24 solid-state reversing contactors, 3-phase

Solid-State Switching Devices for Switching Motors Solid-State Contactors 3RF24 solid-state reversing contactors, three-phase 1) The reduced values in brackets apply to a directly mounted circuit brea- ker and simultaneous butt-mounting. 2) To reduce the risk of a phase short circuit due to overvoltage, we recom- mend using a varistor type 3TX7 462-3L between the phases L1 and L3 and as close as possible to the switchgear. We recommend a design with semiconductor protection as short-circuit protection. 62 Siemens · 2009 Order No. Fuseless design with motor starter protector CLASS 10 Rated operational current IAC-531) Power loss at Short-circuit protection with type of coordination "1" acc.

to IEC 60947-4-2 IAC-53 at an operational voltage of Ue to 440 V UL/CSA, Motor starter protector Iq at 40 °C at 50 °C at 60 °C at 40 °C A A A W Type kA Fuseless design with motor starter protector CLASS 10 Rated operational current IAC-531) acc. to IEC 60947-4-2 Power loss at IAC-53 Short-circuit protection with type of coordination "1" at an operational voltage of Ue to 440 V at 40 °C UL/CSA, at 50 °C at 60 °C at 40 °C Motor starter protector Iq A A W Type kA Main circuit 3RF24 03-.BD.4 3RF24 05-.BD.4 3RF24 10-.BD.4 3.8 (3.4) 3.5 (3.1) 3.2 (2.8) 7 ( 6) 3RV1 021-1FA10 50 5.4 (4.8) 5 (4.3) 4.6 (3.8) 9 ( 8) 3RV1 021-1GA10 50 7.4 6.8 6.2 13 3RV1 021-1JA10 10 Order No.

Fused design with directly connected 3RB20 overload relay Rated operational current IAC-53 Power loss at acc. to IEC 60947-4-2 IAC-53 UL/CSA, at 40 °C at 50 °C at 60 °C at 40 °C A A A W Fused design with directly connected 3RB20 overload relay Minimum load current Max. leakage current Rated impulse withstand capacity Itsm I2t value Rated operational current IAC-53 acc.

to IEC 60947-4-2 Power loss at IAC-53 at 40 °C UL/CSA, at 50 °C at 60 °C at 40 °C A A W A mA A A2s Main circuit 3RF24 03-.BD.4 3RF24 05-.BD.4 3RF24 10-.BD.4 3.8 3.5 3.2 6 0.5 10 200 200 5.4 5 4.6 8 0.5 10 600 1800 7.4 6.8 6.2 16 0.5 10 600 1800 Type 3RF24 ..-.BD.4 Main circuit Controlled phases Two-phase Rated operational voltage Ue2) V • Operating range V • Rated frequency Hz 48 ... 460 40 ... 506 50/60 ± 10 % Rated insulation voltage Ui V 600 Rated impulse withstand voltage Uimp kV 6 Blocking voltage V 1200 Rage of voltage rise V/µs 1000 Type 3RF24 ..-.BD0. 3RF24 ..-.BD2. Control circuit Method of operation DC operation AC operation Rated control supply voltage Us V 24 acc.

to EN 61131-2 110 ... 230 Rated frequency Hz of the control supply voltage -- 50/60 ± 10 % Control supply voltage, maximum V 30 253 Typical actuating current mA 15 10 Response voltage V 15 90 Drop-out voltage V 5 Operating times • ON-delay ms • OFF-delay ms • Interlocking time ms 5 20 5 + max. one half-wave 10 + max. one half-wave 60 ... 100 50 ... 100