omron — 7.4.1. Checking the Connection Status

7. Connection Procedure 7.4. Checking the EtherCAT Communications Confirm that the EtherCAT communications are performed normally. 7.4.1. Checking the Connection Status Check the connection status of the EtherCAT network. 23 1 Check the LED indicators on the Position Control Unit and confirm that the EtherCAT communications are performed normally. (Upper side of Position Control Unit) LED indicators in normal status: [RUN]: Lit green [ERC]: Not lit [ERH]: Not lit [ECAT RUN]: Lit green [ECAT ERR]: Not lit [L/A]: Flickering The 7-segment display shows as follows during normal EtherCAT communications. The 7-segment display:

00 Lit (Lower side of Position Control Unit) (During EtherCAT communications) The status of each LED indicator is shown on the right.