Chapter 2 Overview | CME-PD01 „ The address in PROFIBUS-DP can be set via two rotary address switches, ADDH and ADDL, on CME-PD01: ADDH used as a high 4 bits of address, ADDL used as a low 4 bits of address. NOTE For more information of address switches, refer to Chapter 5 Communication. „ A specific 6-PIN communication cable for RJ-45, is used to connect the CME-PD01 to VFD-E series via RS-485 interface. VFD-E series supply the 15V DC power to CME- „ PROFIBUS-DP interface (DB9) uses a standard PROFIBUS-DP system interface. We PD01 through this cable. recommend users use the standard connector to connect CME-PD01 to PROFIBUS- DP system.

Besides, the CME-PD01 also provides a 4-PIN extended socket for users to connect it to PROFIBUS-DP system based upon the requirements. However, please pay attention to the assignment of A1, B1, and A2, B2 on the 4-PIN extended socket. „ CME-PD01 supports baud rates of 9.6kbaud to 12Mbaud. 2.3 Functionality „ Cyclical process data exchange (PZD). „ Parameter accessing: cyclical accessing of parameters (PKW). „ PROFIBUS supports the control commands SYNC and FREEZE for data synchronization between master and slaves. „ Support the configuration of data structure for data exchange with VFD-E series. 2-2 Revision October 2006, 2006PDD23000013